Advanced electrochemical potential monitoring for improved understanding of electrical neurostimulation protocols

Abstract: Objective. Current-controlled neurostimulation is increasingly used in the clinical treatment of neurological disorders and widely applied in neural prostheses such as cochlear implants. Despite its importance, time-dependent potential traces of electrodes during microsecond-scale current pulses, especially with respect to a reference electrode (RE), are not precisely understood. However, this knowledge is critical to predict contributions of chemical reactions at the electrodes, and ultimately electrode stability, biocompatibility, and stimulation safety and efficacy. Approach. We assessed the electrochemistry of neurostimulation protocols in vitro with Pt microelectrodes from millisecond (classical electroanalysis) to microsecond (neurostimulation) timescales. We developed a dual-channel instrumentation amplifier to include a RE in neurostimulation setups. Uniquely, we combined potential measurements with potentiostatic prepolarization to control and investigate the surface status, which is not possible in typical stimulation setups. Main results. We thoroughly validated the instrumentation and highlighted the importance of monitoring individual electrochemical electrode potentials in different configurations of neurostimulation. We investigated electrode processes such as oxide formation and oxygen reduction by chronopotentiometry, bridging the gap between milli- and microsecond timescales. Our results demonstrate how much impact on potential traces the electrode's initial surface state and electrochemical surface processes have, even on a microsecond scale. Significance. Our unique use of preconditioning in combination with stimulation reveals that interpreting potential traces with respect to electrode processes is misleading without rigorous control of the electrode's surface state. Especially in vivo, where the microenvironment is unknown, simply measuring the voltage between two electrodes cannot accurately reflect the electrode's state and processes. Potential boundaries determine charge transfer, corrosion, and alterations of the electrode/tissue interface such as pH and oxygenation, particularly in long-term in vivo use. Our findings are relevant for all use-cases of constant-current stimulation, strongly advocating for electrochemical in situ investigations in many applications like the development of new electrode materials and stimulation methods

Standort
Deutsche Nationalbibliothek Frankfurt am Main
Umfang
Online-Ressource
Sprache
Englisch
Anmerkungen
Journal of neural engineering. - 20, 3 (2023) , 036036, ISSN: 1741-2552

Ereignis
Veröffentlichung
(wo)
Freiburg
(wer)
Universität
(wann)
2023
Urheber

DOI
10.1088/1741-2552/acdd9d
URN
urn:nbn:de:bsz:25-freidok-2373803
Rechteinformation
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Letzte Aktualisierung
25.03.2025, 13:48 MEZ

Datenpartner

Dieses Objekt wird bereitgestellt von:
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.

Beteiligte

Entstanden

  • 2023

Ähnliche Objekte (12)