Use of the full-thickness resection device (FTRD) to prevent bleeding after colonic polypectomy in a patient with a left ventricular assist device

Abstract: Background and study aims Treatment of colorectal polyps in patients undergoing permanent anticoagulation is associated with a significantly increased risk of peri-interventional bleeding. This specifically applies to polyps > 1 cm where endoscopic full-thickness resection (EFTR) with the full-thickness-resection device (FTRD) can be taken into consideration as an alternative approach to classical snare polypectomy.

For these indications, EFTR appears to be superior to conventional techniques especially in terms of sufficient hemostasis due to the mechanical tissue compression achieved by the FTRDʼs integrated Over-The-Scope Clip (OTSC). This is demonstrated in the following case report of a 59-year-old male with a left ventricular assist device (LVAD) implanted due to congestive heart failure. He presented with intermittent hemorrhage from a large polyp in the ascending colon that was successfully treated via EFTR with the FTRD. A video is included

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Endoscopy International Open. - 05, 08 (2017) , E749-E753, ISSN: 2196-9736

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2019
Creator

DOI
10.1055/s-0043-111593
URN
urn:nbn:de:bsz:25-freidok-1401038
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 10:46 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Time of origin

  • 2019

Other Objects (12)