Water Loss Predictive Tests in Flooded Lead‐Acid Batteries

Abstract: Different aging processes rates of flooded lead–acid batteries (FLAB) depend strongly on the operational condition, yet the difficult to predict presence of certain additives or contaminants could prompt or anticipate the aging. Linear sweep current (LSC) and gas test (GT) characterizations were reported here to fasten the water consumption evaluation. The two methods were proposed to evaluate the water consumption effect at 60 °C, on a custom cell with a (1+ 2−) plate configuration. The predictive ability of the proposed tests was verified on 9 batches of plates for FLAB preliminary tested with the European standard CEI EN 50342‐1: 2019‐11 method. LSC and GT tests showed the capability to identify plate batches with anomalous behaviour for the water consumption and good agreement with the European standard CEI EN 50342‐1: 2019‐11 method. Furthermore, it was found that Tafel parameters determined from LSC and GT tests correlated well with the concentration of Te.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Water Loss Predictive Tests in Flooded Lead‐Acid Batteries ; day:26 ; month:10 ; year:2022 ; extent:1
ChemElectroChem ; (26.10.2022) (gesamt 1)

Creator
Parnigotto, Mattia
Mazzucato, Marco
Fabris, Daniele
Dainese, Lorenzo
Cazzanti, Silvia
Bortolamei, Nicola
Durante, Christian

DOI
10.1002/celc.202200883
URN
urn:nbn:de:101:1-2022102715043502539504
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:35 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Parnigotto, Mattia
  • Mazzucato, Marco
  • Fabris, Daniele
  • Dainese, Lorenzo
  • Cazzanti, Silvia
  • Bortolamei, Nicola
  • Durante, Christian

Other Objects (12)