The “speed” of acuity in scotopic vs. photopic vision

Abstract: Purpose
The effect of duration of optotype presentation on visual acuity measures has been extensively studied under photopic conditions. However, systematic data on duration dependence of acuity values under mesopic and scotopic conditions is scarce, despite being highly relevant for many visual tasks including night driving, and for clinical diagnostic applications. The present study aims to address this void.

Methods
We measured Landolt C acuity under photopic (90 cd/m2), mesopic (0.7 cd/m2), and scotopic (0.009 cd/m2) conditions for several optotype presentation durations ranging from 0.1 to 10 s using the Freiburg Acuity and Contrast Test. Two age groups were tested (young, 18–29 years, and older, 61–74 years).

Results
As expected, under all luminance conditions, better acuity values were found for longer presentation durations. Photopic acuity in young participants decreased by about 0.25 log units from 0.1 to 10 s; mesopic vision mimicked the photopic visual behavior. Scotopic acuities depended more strongly on presentation duration (difference > 0.78 log units) than photopic values. There was no consistent pattern of correlation between luminance conditions across participants. We found a qualitative similarity between younger and older participants, despite higher variability among the latter and differences in absolute acuity: Photopic acuity difference (0.1 vs. 10 s) for the older participants was 0.19 log units, and scotopic difference was > 0.62 log units.

Conclusion
Scotopic acuity is more susceptible to changes in stimulus duration than photopic vision, with considerable interindividual variability. The latter may reflect differences in aging and sub-clinical pathophysiological processes and might have consequences for visual performance during nocturnal activities such as driving at night. Acuity testing with briefly presented scotopic stimuli might increase the usefulness of acuity assessment for tracking of the health state of the visual system

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Graefe's archive for clinical and experimental ophthalmology. - 258, 12 (2020) , 2791-2798, ISSN: 1435-702X

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2020
Creator

DOI
10.1007/s00417-020-04867-6
URN
urn:nbn:de:bsz:25-freidok-1701929
Rights
Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:32 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2020

Other Objects (12)