Non-unions and wound infections do not differ following intramedullary nailing and plate osteosynthesis for distal third femur fractures: a meta-analysis

Abstract: Purpose
The fixation method of distal, extra-articular femur fractures is a controversially discussed. To ensure better stability itself, earlier mobilization and to prevent blood loss – all these are justifications for addressing the femur via reamed intramedullary nailing (RIMN). Anatomical reposition of multifragmentary fractures followed by increased risks of non-union are compelling reasons against it. The purpose of this study was to systematically review the literature for rates of non-union and wound infection, as well as blood loss and time of surgery.

Methods
According to the PRISMA guidelines we conducted this systematic review by searching the Cochrane, PubMed, Ovid, MedLine, and Embase databases. Inclusion criteria were the modified Coleman methodology score (mCMS) >60, age >18 years, and extra-articular fractures of the distal femur. Biomechanical and animal studies were excluded. By referring to title and abstract relevant articles were reviewed independently. In the consecutive meta-analysis, we compared 9 studies and 639 patients.

Results
There is no statistically significant difference comparing superficial wound infections when RIMN was performed (OR = 0.50; 95% CI: 0.18 – 1.42; P = 0.19) as well as in deep wound infections (OR = 0.74; 95% CI: 0.19–2.81; P = 0.62). However, these results were not significant. We also calculated for potential differences in the rate of non-unions depending on the surgical treatment applied. Data of 556 patients revealed an overall number of 43 non-unions. There was no significant difference in rate of non-unions between both groups (OR = 0.97; 95% CI: 0.51–1.85; P = 0.92).

Conclusion
No statistical difference was found in our study among RIMN and plate fixation in the treatment of distal femoral fractures with regard to the incidence of non-union and wound infections. Therefore, the indication for RIMN or plating should be made individually and based on the surgeon’s experience

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
EFORT open reviews. - 9, 3 (2024) , 210-216, ISSN: 2058-5241

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2024

DOI
10.1530/eor-22-0140
URN
urn:nbn:de:bsz:25-freidok-2461288
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
25.03.2025, 1:50 PM CET

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2024

Other Objects (12)