Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial

Abstract: Purpose
The AT LARA 829MP is a next-generation extended depth of focus (EDOF) intraocular lens (IOL) providing continuous vision over a range of distances. The aim of this prospective multi-centre randomised trial was to compare two EDOF IOLs and one monofocal IOL.

Methods
Cataract patients between 50 and 80 years were randomised for bilateral implantation with either the AT LARA 829MP (EDOF), the TECNIS Symfony (EDOF) or the CT ASPHINA 409MP (monofocal). Follow-up was at 1 to 2 weeks, 1 month and 4 to 6 months.

Results
A total of 211 patients were randomised and included in the final analysis. Monocular depth of focus was significantly better for AT LARA 829MP eyes compared with that for TECNIS Symfony at all thresholds (p = 0.024, 0.001 and 0.006, for 0.1, 0.2 and 0.3 logMAR respectively) with no significant difference for binocular depth of focus. LARA eyes had significantly better monocular depth of focus at all levels compared with ASPHINA eyes (all p < 0.0001), while there was no significant difference between Symfony and ASPHINA eyes at 0.1 logMAR and 0.2 logMAR. Both EDOF IOLs were significantly better than the monofocal ASPHINA at all levels for binocular depth of focus (LARA: all p < 0.0001; Symfony: all p = 0.002). Distance visual acuity was similar for all IOLs at 6 months; intermediate and near visual acuity were significantly better for the EDOF IOLs than for the monofocal (p < 0.0001). Refraction improved in all groups relative to baseline. Contrast sensitivity was higher with the CT ASPHINA 409MP but both EDOF lenses had a better spectacle independence rate. At 6 months, all IOLs were well centred with no cases of tilt. No general safety issues were raised for any of the groups.

Conclusion
The two EDOF intraocular lenses investigated provided good visual outcomes with comparable visual acuity at all distances. The AT LARA 829MP provided the widest monocular depth of focus at 0.1 and 0.2 logMAR, with a clear superiority compared with the monofocal IOL. TECNIS Symfony was superior to the monofocal control at 0.3 logMAR. Spectacle independence and patient satisfaction were comparable

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Graefe's archive for clinical and experimental ophthalmology. - 259 (2021) , 431–442, ISSN: 1435-702X

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2020
Creator
Reinhard, Thomas
Maier, Philip
Böhringer, Daniel
Bertelmann, Eckart
Brockmann, Tobias
Kiraly, Laszlo
Salom, David
Piovella, Matteo
Colonval, Stephane
Mendicute, Javier

DOI
10.1007/s00417-020-04868-5
URN
urn:nbn:de:bsz:25-freidok-1745528
Rights
Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:37 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2020

Other Objects (12)