CT and MRI radiomics of bone and soft-tissue sarcomas: an updated systematic review of reproducibility and validation strategies

Abstract: Objective
To systematically review radiomic feature reproducibility and model validation strategies in recent studies dealing with CT and MRI radiomics of bone and soft-tissue sarcomas, thus updating a previous version of this review which included studies published up to 2020.

Methods
A literature search was conducted on EMBASE and PubMed databases for papers published between January 2021 and March 2023. Data regarding radiomic feature reproducibility and model validation strategies were extracted and analyzed.

Results
Out of 201 identified papers, 55 were included. They dealt with radiomics of bone (n = 23) or soft-tissue (n = 32) tumors. Thirty-two (out of 54 employing manual or semiautomatic segmentation, 59%) studies included a feature reproducibility analysis. Reproducibility was assessed based on intra/interobserver segmentation variability in 30 (55%) and geometrical transformations of the region of interest in 2 (4%) studies. At least one machine learning validation technique was used for model development in 34 (62%) papers, and K-fold cross-validation was employed most frequently. A clinical validation of the model was reported in 38 (69%) papers. It was performed using a separate dataset from the primary institution (internal test) in 22 (40%), an independent dataset from another institution (external test) in 14 (25%) and both in 2 (4%) studies.

Conclusions
Compared to papers published up to 2020, a clear improvement was noted with almost double publications reporting methodological aspects related to reproducibility and validation. Larger multicenter investigations including external clinical validation and the publication of databases in open-access repositories could further improve methodology and bring radiomics from a research area to the clinical stage.

Critical relevance statement
An improvement in feature reproducibility and model validation strategies has been shown in this updated systematic review on radiomics of bone and soft-tissue sarcomas, highlighting efforts to enhance methodology and bring radiomics from a research area to the clinical stage.

Key points

• 2021–2023 radiomic studies on CT and MRI of musculoskeletal sarcomas were reviewed.

• Feature reproducibility was assessed in more than half (59%) of the studies.

• Model clinical validation was performed in 69% of the studies.

• Internal (44%) and/or external (29%) test datasets were employed for clinical validation

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Insights into imaging. - 15, 1 (2024) , 54, ISSN: 1869-4101

Classification
Medizin, Gesundheit

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2024
Creator
Gitto, Salvatore
Cuocolo, Renato
Huisman, Merel
Messina, Carmelo
Albano, Domenico
Omoumi, Patrick
Kotter, Elmar
Maas, Mario
van Ooijen, Peter
Sconfienza, Luca Maria

DOI
10.1186/s13244-024-01614-x
URN
urn:nbn:de:bsz:25-freidok-2469790
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 11:01 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2024

Other Objects (12)