Scotopic and photopic conventional visual acuity and hyperacuity – binocular summation

Abstract: Purpose: The purpose of this study was to determine and compare binocular summation (BiS) of conventional visual acuity (cVA) versus hyperacuity (hVA) for photopic and scotopic luminance conditions as a potential biomarker to assess the outcome of interventions on binocular function.

Methods: Sixteen young adults (age range [years] = 21–31; 8 women; cVA logMAR < 0.0) participated in this study. The Freiburg Visual Acuity Test (FrACT) was used for VA testing and retested on another day. Both cVA and hVA were determined for dark grey optotypes on light grey background. Participants underwent 40 minutes of dark adaptation prior to scotopic VA testing. Binocular and monocular VA testing was performed. The eye with better VA over the 2 days of testing was selected, the BiS was quantified (binocular VA – better monocular VA) and repeated measures ANOVAs were performed.

Results: Binocular VA exceeded monocular VA for all luminance conditions, VA-types, and sessions. We report BiS estimates for photopic and scotopic cVA and hVA, (logMAR BiS ± SEM [decimal BiS]): photopic = −0.01 ± 0.01 [1.03] and −0.06 ± 0.03 [1.15]; and scotopic = −0.05 ± 0.01 [1.12] and −0.11 ± 0.04 [1.28], respectively). Improvement for binocular vision estimates ranged from 0.01 to 0.11 logMAR. A repeated-measures ANOVA (RM ANOVA) did not reveal significant effects of LUMINANCE or VA TYPE on BiS, albeit a trend for strongest BiS for scotopic hVA (15% vs. 28%, photopic versus scotopic, respectively) and weakest for photopic cVA (3% vs. 12%, photopic versus scotopic conditions, respectively).

Conclusions: Our results indicate that BiS of VA is relevant to scotopic and photopic hVA and cVA. It appears therefore a plausible candidate biomarker to assess the outcome of retinal therapies restoring rod or cone function on binocular vision.

Translational Relevance: Binocular summation of visual acuity might serve as a clinical biomarker to monitor therapy outcome on binocular rod and cone-mediated vision

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Translational Vision Science & Technology. - 13, 4 (2024) , 25, ISSN: 2164-2591

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2024
Creator
Korn, Sophie
Al-Nosairy, Khaldoon
Gopiswaminathan, Akshara V.
João, Catarina
Scanferla, Lorenzo
Bach, Michael
Hoffmann, Michael

DOI
10.1167/tvst.13.4.25
URN
urn:nbn:de:bsz:25-freidok-2469290
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 11:03 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2024

Other Objects (12)