Dielectric electroactive polymer membrane actuator with ring-type electrode as driving component of a tactile actuator
Abstract: We present a driving concept of a tactile actuator based on a dielectric electroactive polymer using a ring-type electrode. This electrode is located around a deflectable membrane. The fabrication process and tests of the tactile actuator including integration into a hydraulic amplifier design are presented proving the concept of the novel actuation. The tactile actuator exhibits a maximum measured deflection of 124±7 μ m for an applied voltage of 4200 V. The membrane thickness and the total thickness of the actuator including hydraulic amplifier were 30 and about 570 μ m, respectively
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Anmerkungen
-
Procedia engineering. - 168 (2016) , 1537-1540, ISSN: 1877-7058
- Ereignis
-
Veröffentlichung
- (wo)
-
Freiburg
- (wer)
-
Universität
- (wann)
-
2019
- Beteiligte Personen und Organisationen
- DOI
-
10.1016/j.proeng.2016.11.455
- URN
-
urn:nbn:de:bsz:25-freidok-1434156
- Rechteinformation
-
Kein Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
-
25.03.2025, 13:52 MEZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
Entstanden
- 2019