Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography—A Prospective Study

Abstract: Introduction Pulmonary embolism is the third most common cause of cardiovascular death worldwide and imaging plays a pivotal role in establishing the diagnosis. Computed tomography pulmonary angiography (CTPA) scores over other modalities and is the current diagnostic investigation of choice. In this study, we assessed the main pulmonary artery and its corresponding segmental artery attenuation in reconstructed virtual monoenergetic (mono plus) images (VMI-MP) and linear blended images (spectral post processing, SPP) obtained from dual-energy CTPA. The values were compared using contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). Materials and Methods Forty patients (mean age group, 53.6 years; 26 females and 14 males) with segmental pulmonary thromboembolism were included in this prospective study. The patients underwent CTPA study using bolus tracking in the dual-source CT-SOMATOM Force, Siemens. Postcontrast datasets (90 kV, 150 kV, and SPP) were used to reconstruct the monoenergetic images using syngo.via software virtually. Comparison was done between bivariate samples using the paired sample t-test. Results The mean Hounsfield unit (HU) artery in the left lung for VMI-MP and SPP images were 886.9 ± 242 and 356.8 ± 121.3 HU, respectively. Similarly, for the right lung, it was 868.3 ± 243.5 and 336.1 ± 105.5 HU, respectively. The mean attenuation of the arteries in MP images was higher and statistically significant (p-value <0.005). Likewise, the CNR) and SNR were found to have a statistically significant p-value (<0.005). An acceptable increase in image noise was seen in VMI as compared with SPP images. Conclusion Low-keV VMIs perform more effectively than the conventional polyenergetic spectrum to evaluate vessel attenuation, which in turn increases thrombus detectability. The increased CNR in VMI enables improved lesion conspicuity.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography—A Prospective Study ; day:03 ; month:09 ; year:2024
The Indian journal of radiology and imaging ; (03.09.2024)

Contributor
Ethiraju, Vijayakumaran
Varatharajaperumal, Rajeshkumar
Arunachalam, Venkatesh Kasi
KuruVambath, Abdulla
Punniyakotti, Rajesh Shanmugam
Rajasekaran, Sriman
Mehta, Pankaj
Cherian, Mathew

DOI
10.1055/s-0044-1788575
URN
urn:nbn:de:101:1-2410311214477.922421457957
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:37 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Ethiraju, Vijayakumaran
  • Varatharajaperumal, Rajeshkumar
  • Arunachalam, Venkatesh Kasi
  • KuruVambath, Abdulla
  • Punniyakotti, Rajesh Shanmugam
  • Rajasekaran, Sriman
  • Mehta, Pankaj
  • Cherian, Mathew

Other Objects (12)