Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring

Abstract: Background Early detection of free flap compromise is critical for salvage of the flap. Various methods of free flap monitoring have been described, but clinical assessment is the standard method for among all. In this study, role of infrared thermography is evaluated for free flap monitoring. Methods In patients undergoing free flap surgery, monitoring was done using standard clinical parameters and infrared thermography as per our institutional protocol. Mean temperature difference (∆T) between the flap and the surrounding skin was calculated using the temperature readings from the thermal images intra- and postoperatively. The accuracy of infrared thermography in flap monitoring was assessed in comparison to the standard clinical protocol. Results Forty-one flaps were included in the analysis, out of which five flaps got compromised. It was observed that the mean temperature difference was higher (mean ∆T 0.20–0.59 vs. 2.38–3.32) when there was a flap compromise, and this temperature difference was evident even before the development of clinical signs. The temperature difference in venous thrombosis (mean ∆T 1.0–2.7) was found to be slightly lower than in arterial insufficiency (mean ∆T 2.1–4.4). For a ∆T cutoff value of 2°C, the thermal camera had a sensitivity of 88.6%, specificity of 98.9%, positive predictive value of 93.9%, and negative predictive value of 97.7%. Conclusion Infrared thermography is a valuable and noninvasive objective tool in free flap monitoring, which can detect flap compromise (increasing value of ∆T) even before it becomes clinically evident.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Free Flap Monitoring Using Infrared Thermography: An Objective Adjunct to Clinical Monitoring ; day:10 ; month:05 ; year:2024
Indian journal of plastic surgery ; (10.05.2024)

Contributor
Singla, Priyanka
Dixit, Pawan Kumar
Kala, Prakash Chandra
Katrolia, Deepti
Karmakar, Shilpi
Humnekar, Akhilesh
Singh, Apoorva Pratap

DOI
10.1055/s-0044-1786742
URN
urn:nbn:de:101:1-2406271014143.916185885915
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 10:49 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Singla, Priyanka
  • Dixit, Pawan Kumar
  • Kala, Prakash Chandra
  • Katrolia, Deepti
  • Karmakar, Shilpi
  • Humnekar, Akhilesh
  • Singh, Apoorva Pratap

Other Objects (12)