Accuracy of digital and conventional implant impressions in edentulous jaws: a clinical comparative study

Abstract: Objectives
This clinical study aimed to evaluate the accuracy of digital and conventional implant impressions in a fully edentulous maxilla and mandible.
Methods
A 53-year-old edentulous patient with four maxillary and two mandibular implants was selected. Ten intraoral scans (IOS) and a conventional impression per jaw were taken. Clinically verified upper and lower plaster models were digitized using both optical (reference data, n = 10 per model) and tactile laboratory scanner (n = 10 per model). Accuracy was evaluated by comparing the precision and linear/angular deviations of the implants with the reference data. Statistical analyses were conducted using Student's t-test and Kruskal–Wallis test (α = 0.05).
Results
In the maxilla, the most significant linear deviations exceeding the 100 µm threshold were found with IOS between implants 1–4. In the mandible, all linear deviations remained below 55 µm. Angular deviations between implants after IOS ranged from 0.01° to 0.40° in the mandible and <0.01° to 1.86° in the maxilla. After tactile scanning, linear deviations did not exceed 100 µm threshold (except in one distance) and angular deviations ranged from 0.04° to 0.54° (mandible) and <0.01° to 2.50° (maxilla). The optical scanner demonstrated significantly higher precision (p < 0.001) compared to the IOS and tactile scanner.
Conclusions
Given the significant deviations observed, especially in the maxilla, the optical scanner following conventional impressions remained the preferred method for fully edentulous cases due to its superior accuracy.
Clinical significance
IOS could be a viable alternative particularly for shorter distances in the edentulous jaw, although the clinical implications of these deviations need to be investigated in future studies

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch
Notes
Journal of dentistry. - 153 (2025) , 105559, ISSN: 1879-176X

Event
Veröffentlichung
(where)
Freiburg
(who)
Universität
(when)
2025
Creator

DOI
10.1016/j.jdent.2025.105559
URN
urn:nbn:de:bsz:25-freidok-2621118
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:37 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Time of origin

  • 2025

Other Objects (12)