Thermal-strength analysis of a cross-flow heat exchanger and its design improvement

Abstract: After a year of the heat exchanger operation in overload conditions, a number of cracks on the tube connections to the tubesheet have been observed. To explain the stress concentration and crack initiation, a finite element analysis is performed. A three-dimensional model is constructed and analyzed. To calculate more precisely the state of stress in the most loaded regions, a submodel is created. The maximum stress exceeds the allowable stress, and according to the standards, it can lead to ratcheting. To reduce stress concentration, all tubes should be shortened and corrugated tubes are installed in the high-temperature region from the side of the burner. A finite element model of the modified heat exchanger and a submodel are created. In the modified heat exchanger, ratcheting should not occur according to the applied standards. During the operation of the modified heat exchanger, there are no further problems with cracking.

Standort
Deutsche Nationalbibliothek Frankfurt am Main
Umfang
Online-Ressource
Sprache
Englisch

Erschienen in
Thermal-strength analysis of a cross-flow heat exchanger and its design improvement ; volume:11 ; number:1 ; year:2021 ; pages:1069-1075 ; extent:7
Open engineering ; 11, Heft 1 (2021), 1069-1075 (gesamt 7)

Urheber
Konieczny, Mariusz
Felkowski, Łukasz

DOI
10.1515/eng-2021-0105
URN
urn:nbn:de:101:1-2412141733264.627288166178
Rechteinformation
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Letzte Aktualisierung
15.08.2025, 07:27 MESZ

Datenpartner

Dieses Objekt wird bereitgestellt von:
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.

Beteiligte

  • Konieczny, Mariusz
  • Felkowski, Łukasz

Ähnliche Objekte (12)