Comparison of three methods for determining anti-thyrotropin receptor antibodies (TRAb) for diagnosis of Graves’ disease: a clinical validation

Objectives: Graves’ disease is secondary to the presence of anti-thyrotropin receptor antibodies (TRAb), which stimulate thyroid hormones. TRab determination is crucial for etiological diagnosis. The objectives of this study were (i) to compare two methods for determining TRab by chemoluminiscence vs. standard TRACE-immunofluorescence; (ii) to determine the diagnostic validity of the three methods. Methods: A retrospective study in 194 patients with a TRAb determination request. TRAb were determined by immunofluorescence (Kryptor, ThermoFisher) and chemiluminescence (Immulite, Siemens and Maglumi, Snibe). Clinical validation: medical records were reviewed and categorized according to thyroid function. Statistical analysis: Differences in quantitative variables were assessed by intraclass correlation coefficient, Bland–Altman plot, and mean differences (mD). Qualitative variables were dichotomized by cut-off points; Kappa coefficient was calculated. Correlations were evaluated by Pearson’s coefficient and Passing-Bablok regression analysis. The diagnostic validity of the three methods was investigated. Results: Kryptor-Immulite: mD: 1.2 (95%CI: −16 to >18). Passing-Bablok: Constant error (95%CI: −0.8349 to −0.5987). Proportional error (95%CI: 0.7862–1.0387). ICC: 0.86 (95%CI: 0.82–0.89). Kappa coefficient: 0.68 (95%CI 0.59–0.78). Kryptor-Maglumi: mD: −0.3 (95%CI: −12 to >12). Passing-Bablok: Constant error (95%CI: −0.7701 to >0.1621. Proportional error (95%CI: 0.8571 to 1.3179. ICC: 0.93 (95%CI: 0.89–0.97). Kappa coefficient: 0.53 (95%CI: 0.32–0.74). Diagnosis of Graves’ disease was confirmed in 113 patients (Kryptorf showed better specificity and positive predictive value, whereas Immulite demonstrated better sensitivity and negative predictive value). Conclusions: The three methods have a good diagnostic performance for Graves’ disease, with superimposable results on Bland–Altman plot. Interchangeability was not confirmed on the regression and agreement analysis, with the presence of biases.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Comparison of three methods for determining anti-thyrotropin receptor antibodies (TRAb) for diagnosis of Graves’ disease: a clinical validation ; volume:2 ; number:2 ; year:2021 ; pages:221-227 ; extent:07
Advances in laboratory medicine ; 2, Heft 2 (2021), 221-227 (gesamt 07)

Creator
Silvestre, Ramona A.
Almería Lafuente, Alejandro
Jiménez-Mendiguchía, Lucía
García-Cano, Ana
Romero López, Rubén
García-Izquierdo, Belén
Pardo de Santayana, Cristina
Iglesias, Pedro
Diez, Juan J.
Arribas Gómez, Ignacio
Bernabeu-Andreu, Francisco A.

DOI
10.1515/almed-2021-0015
URN
urn:nbn:de:101:1-2023061414080058141072
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 10:47 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Silvestre, Ramona A.
  • Almería Lafuente, Alejandro
  • Jiménez-Mendiguchía, Lucía
  • García-Cano, Ana
  • Romero López, Rubén
  • García-Izquierdo, Belén
  • Pardo de Santayana, Cristina
  • Iglesias, Pedro
  • Diez, Juan J.
  • Arribas Gómez, Ignacio
  • Bernabeu-Andreu, Francisco A.

Other Objects (12)