Pre-Descemetic Placement of Intracorneal Ring Segments for Keratoconus after Mechanical Implantation

We report the case of a 23-year-old male who was referred to our clinic for a routine follow-up examination. The patient was treated for keratoconus 3 years ago in Colombia, where intracorneal ring segments were implanted mechanically in both eyes to improve his visual acuity. Surprisingly, we discovered a pre-descemetic placement of intracorneal ring segments, which could lead to potential complications, under circumstances. We illustrate this impressive finding with slit-lamp photography and high-resolution anterior segment OCT and advocate for the use of femtosecond laser as the method of choice for intracorneal ring segment insertion in order to provide maximal precision and safety.

Standort
Deutsche Nationalbibliothek Frankfurt am Main
Umfang
Online-Ressource
Sprache
Englisch

Erschienen in
Pre-Descemetic Placement of Intracorneal Ring Segments for Keratoconus after Mechanical Implantation ; volume:12 ; number:3 ; year:2021 ; pages:940-943 ; extent:4
Case reports in ophthalmology ; 12, Heft 3 (2021), 940-943 (gesamt 4)

Urheber
Yahya, Faady
Prünte, Christian F.
Scholl, Hendrik P.N.
Gatzioufas, Zisis

DOI
10.1159/000520571
URN
urn:nbn:de:101:1-2022011223570400883189
Rechteinformation
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Letzte Aktualisierung
15.08.2025, 07:21 MESZ

Datenpartner

Dieses Objekt wird bereitgestellt von:
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.

Beteiligte

  • Yahya, Faady
  • Prünte, Christian F.
  • Scholl, Hendrik P.N.
  • Gatzioufas, Zisis

Ähnliche Objekte (12)