Automatic-Scoring Actigraph Compares Favourably to a Manually-Scored Actigraph for Sleep Measurement in Healthy Adults

Abstract: Introduction Actigraphy has been used widely in sleep research due to its non-invasive, cost-effective ability to monitor sleep. Traditionally, manually-scored actigraphy has been deemed the most appropriate in the research setting; however, technological advances have seen the emergence of automatic-scoring wearable devices and software. Methods A total of 60-nights of sleep data from 20-healthy adult participants (10 male, 10 female, age: 26 ± 10 years) were collected while wearing two devices concomitantly. The objective was to compare an automatic-scoring device (Fatigue Science Readiband™ [AUTO]) and a manually-scored device (Micro Motionlogger® [MAN]) based on the Cole-Kripke method. Manual-scoring involved trained technicians scoring all 60-nights of sleep data. Sleep indices including total sleep time (TST), total time in bed (TIB), sleep onset latency (SOL), sleep efficiency (SE), wake after sleep onset (WASO), wake episodes per night (WE), sleep onset time (SOT) and wake time (WT) were assessed between the two devices using mean differences, 95% levels of agreement, Pearson-correlation coefficients (r), and typical error of measurement (TEM) analysis. Results There were no significant differences between devices for any of the measured sleep variables (p ≥0.05). All sleep indices resulted in very-strong correlations (all r ≥0.84) between devices. A mean difference between devices of <1 minutes for TST was associated with a TEM of 15.5 minute (95% CI =12.3 to 17.7 minutes). Conclusion Given there were no significant differences between devices in the current study, automatic-scoring actigraphy devices may provide a more practical and cost-effective alternative to manually-scored actigraphy in healthy populations.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Automatic-Scoring Actigraph Compares Favourably to a Manually-Scored Actigraph for Sleep Measurement in Healthy Adults ; volume:16 ; number:02 ; year:2023 ; pages:159-164
Sleep science ; 16, Heft 02 (2023), 159-164

Contributor
Edgar, David T.
Beaven, C. Martyn
D. Gill, Nicholas
L. Zaslona, Jennifer
W. Driller, Matthew

DOI
10.1055/s-0043-1770809
URN
urn:nbn:de:101:1-2023082410081828105509
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 10:44 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Edgar, David T.
  • Beaven, C. Martyn
  • D. Gill, Nicholas
  • L. Zaslona, Jennifer
  • W. Driller, Matthew

Other Objects (12)