Evaluation of the effects of different lightning protection rods on the data quality of C-band weather radars

Abstract Z Z R - 15 dB in apparent side-lobe levels is found for all tested lightning protection options. Beam blockage is substantially reduced compared to the existing lightning protection, as shown by the evaluation of quantitative precipitation estimation (QPE) sums. These results and some structural considerations are a solid basis to recommend the installation of four rods with a maximum 40 mm diameter for all 17 radar systems of the DWD weather radar network.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Evaluation of the effects of different lightning protection rods on the data quality of C-band weather radars ; volume:17 ; number:15 ; year:2024 ; pages:4695-4707 ; extent:13
Atmospheric measurement techniques ; 17, Heft 15 (2024), 4695-4707 (gesamt 13)

Creator
Hald, Cornelius
Schaper, Maximilian
Böhm, Annette
Frech, Michael
Petersen, Jan
Lange, Bertram
Rohrdantz, Benjamin

DOI
10.5194/amt-17-4695-2024
URN
urn:nbn:de:101:1-2408150420058.783868063508
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
14.08.2025, 10:57 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Hald, Cornelius
  • Schaper, Maximilian
  • Böhm, Annette
  • Frech, Michael
  • Petersen, Jan
  • Lange, Bertram
  • Rohrdantz, Benjamin

Other Objects (12)