Minimally Invasive Aortic Valve Replacement in Contemporary Practice: Clinical and Hemodynamic Performance from a Prospective Multicenter Trial

Abstract: Background The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. Methods Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. Results Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47–1.55, p = 0.61). Conclusions Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.

Standort
Deutsche Nationalbibliothek Frankfurt am Main
Umfang
Online-Ressource
Sprache
Englisch

Erschienen in
Minimally Invasive Aortic Valve Replacement in Contemporary Practice: Clinical and Hemodynamic Performance from a Prospective Multicenter Trial ; day:29 ; month:05 ; year:2022
The thoracic and cardiovascular surgeon ; (29.05.2022)

Beteiligte Personen und Organisationen
Velders, Bart J.J.
Vriesendorp, Michiel D.
Reardon, Michael J.
Rao, Vivek
Lange, Rüdiger
Patel, Himanshu J.
Gearhart, Elizabeth
Sabik, Joseph F.
Klautz, Robert J.M.

DOI
10.1055/s-0042-1743593
URN
urn:nbn:de:101:1-2022072110511857938807
Rechteinformation
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Letzte Aktualisierung
15.08.2025, 07:38 MESZ

Datenpartner

Dieses Objekt wird bereitgestellt von:
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.

Beteiligte

  • Velders, Bart J.J.
  • Vriesendorp, Michiel D.
  • Reardon, Michael J.
  • Rao, Vivek
  • Lange, Rüdiger
  • Patel, Himanshu J.
  • Gearhart, Elizabeth
  • Sabik, Joseph F.
  • Klautz, Robert J.M.

Ähnliche Objekte (12)