Comparison of the Operating Range of a Wetted‐Wall Column with a Packed Column for Distillation
Abstract: In this paper, a newly designed distillation column consisting of a wetted wall with a rectangular cross section is analyzed and compared with a conventional packed column with regard to the operating range of both apparatuses. As expected, the pressure drop is considerably lower in the wetted‐wall column and, therefore, it offers a higher range of operation. However, in the wetted‐wall column, the separation efficiency decreases rapidly with increasing F factors. This effect can be overcome by the serial connection of two wetted‐wall columns.
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Erschienen in
-
Comparison of the Operating Range of a Wetted‐Wall Column with a Packed Column for Distillation ; volume:92 ; number:12 ; year:2020 ; pages:1968-1975 ; extent:8
Chemie - Ingenieur - Technik ; 92, Heft 12 (2020), 1968-1975 (gesamt 8)
- Urheber
- DOI
-
10.1002/cite.202000065
- URN
-
urn:nbn:de:101:1-2022062310035844964210
- Rechteinformation
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
-
15.08.2025, 07:28 MESZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
- Reitze, Arnulf
- Grünewald, Marcus
- Riese, Julia