Sensation thresholds in electrocutaneous stimulation

Abstract: Acoustic or visual warning signals for workers in hazardous situations might fail under loud and/or lowvisibility work situations. A warning system should be developed that uses electrocutaneous stimulation through textile electrodes. Previous work investigated suitable stimulation parameters using TENS electrodes. The aim of this study was to compare TENS and textile cuff electrodes in terms of sensation thresholds, qualitative and spatial sensation. A study on 30 healthy volunteers (f=13, m=17) of mean age of 26.7 years was conducted applying bi-phasic rectangular current pulses to electrodes attached to the upper right arm. The study revealed that perception, attention and intolerance thresholds, qualitative and spatial perception are comparable indicating that future studies with the textile cuff electrodes can be generally based on the previous results with TENS electrodes.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Sensation thresholds in electrocutaneous stimulation ; volume:6 ; number:3 ; year:2020 ; pages:372-375 ; extent:4
Current directions in biomedical engineering ; 6, Heft 3 (2020), 372-375 (gesamt 4)

Creator
Dölker, Eva-Maria
Mubin, Alkisah binti
Supriyanto, Eko
Haase, Elke
Krzywinski, Sybille
Haueisen, Jens

DOI
10.1515/cdbme-2020-3096
URN
urn:nbn:de:101:1-2022101215270448902734
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:36 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

Other Objects (12)