Quantifying particulate matter optical properties and flow rate in industrial stack plumes from the PRISMA hyperspectral imager
Abstract µ m. We found a volume fraction of soot of 3.6 % and 10.4 % in the sinter plant and coal-fired plant plumes, respectively. The mass flow rate of particulate matter at a point source estimated by an integrated mass enhancement method varies from 840 ± - 1 ± - 1 at the coal-fired plant.
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Erschienen in
-
Quantifying particulate matter optical properties and flow rate in industrial stack plumes from the PRISMA hyperspectral imager ; volume:17 ; number:1 ; year:2024 ; pages:57-71 ; extent:15
Atmospheric measurement techniques ; 17, Heft 1 (2024), 57-71 (gesamt 15)
- Urheber
-
Calassou, Gabriel
Foucher, Pierre-Yves
Léon, Jean-François
- DOI
-
10.5194/amt-17-57-2024
- URN
-
urn:nbn:de:101:1-2024011103141970155662
- Rechteinformation
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
-
26.04.2025, 07:33 MESZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
- Calassou, Gabriel
- Foucher, Pierre-Yves
- Léon, Jean-François