Precise glucose measurement in sodium fluoride-citrate plasma affects estimates of prevalence in diabetes and prediabetes
Objectives: Estimates of glucose concentrations vary among types of blood samples, which impact on the assessment of diabetes prevalence. Guidelines recommend a conversion factor to calculate plasma glucose from measurements of glucose in whole blood. The American Diabetes Association recommends the use of blood drawing tubes containing sodium fluoride (NaF) and citrate, which have not yet been evaluated regarding possible differences in glucose concentration and conversion factors. Thus, we compared glucose measurements in NaF-citrate plasma and venous whole blood and estimated the impact of differences on diabetes and prediabetes prevalence. Methods: Glucose differences were calculated by Bland-Altman analysis with pairwise comparison of glucose measurements from whole blood and NaF-citrate plasma (n=578) in clinical studies of the German Diabetes Center. Subsequently, we computed the impact of the glucose difference on diabetes and prediabetes prevalence in the population-based National Health and Nutrition Examination Survey (NHANES). Results: Even upon conversion of whole blood to plasma glucose concentrations using the recommended conversion factor, mean glucose concentration difference remained 4.72 % higher in NaF-citrate plasma. Applying the higher glucose estimates, increases the population-based diabetes and prediabetes prevalence by 13.67 and 33.97 % or more than 7.2 and 13 million people in NHANES, respectively. Additional economic burden could be about 20 $ billion per year due to undiagnosed diabetes. Conclusions: The recommended conversion factor is not valid for NaF-citrate plasma. Systematic bias of glucose measurements due to sampling type leads to clinically relevant higher estimates of diabetes and prediabetes prevalence.
- Location
-
Deutsche Nationalbibliothek Frankfurt am Main
- Extent
-
Online-Ressource
- Language
-
Englisch
- Bibliographic citation
-
Precise glucose measurement in sodium fluoride-citrate plasma affects estimates of prevalence in diabetes and prediabetes ; volume:62 ; number:4 ; year:2024 ; pages:762-769 ; extent:08
Clinical chemistry and laboratory medicine ; 62, Heft 4 (2024), 762-769 (gesamt 08)
- Creator
-
Heilmann, Geronimo
Trenkamp, Sandra
Möser, Clara
Bombrich, Maria
Schön, Martin
Yurchenko, Iryna
Strassburger, Klaus
Rodríguez, Marcos Matabuena
Zaharia, Oana-Patricia
Burkart, Volker
Wagner, Robert
Roden, Michael
- DOI
-
10.1515/cclm-2023-0770
- URN
-
urn:nbn:de:101:1-2024022713040260269123
- Rights
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Last update
-
14.08.2025, 11:03 AM CEST
Data provider
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.
Associated
- Heilmann, Geronimo
- Trenkamp, Sandra
- Möser, Clara
- Bombrich, Maria
- Schön, Martin
- Yurchenko, Iryna
- Strassburger, Klaus
- Rodríguez, Marcos Matabuena
- Zaharia, Oana-Patricia
- Burkart, Volker
- Wagner, Robert
- Roden, Michael