Minimum irradiance required to inhibit microbial growth to prevent ventilatorassociated pneumonia by an endotracheal tube equipped with blue LEDs

Abstract: Artificial respiration is saving lives especially in the COVID-19 pandemic, but it also carries the risk to cause ventilator-associated pneumonia (VAP). VAP is one of the most common and severe nosocomial infections, often leading to death and adding a major economic burden to the healthcare system. To prevent a proliferation of microbial pathogens that cause VAP, an endotracheal tube (ETT) equipped with blue LEDs (LED-ETT) was developed. This blue wavelength exhibits antimicrobial properties but may also harm human tracheal cells at higher irradiances. Therefore, the aim of this study was to find the minimal required irradiance for microbial reduction of 1 log level in 24 h by applying LED-ETTs. A LED-ETT with 48 blue LEDs (450 nm) was fixed in a glass tube, which served as a trachea model. The investigation was carried out with irradiations of 4.2, 6.6 and 13.4 mW/cm² at 37 °C for 24 h. The experiments were performed with Acinetobacter kookii as a surrogate of Acinetobacter baumannii, which is classified as critical by the WHO. Samples of A. kookii suspensions were taken every 4 h during irradiation from the trachea model. Bacteria concentrations were quantified by determining colony forming units (CFU)/ml. A homogeneous irradiance of only 4.2 mW/cm² generated by the blue LEDs, at a LED forward current of 3.125 mA, is sufficient to achieve a 1 log reduction of A. kookii within 24 h. The total irradiation dose within this period was 360 J/cm2. Human cells survive this dose without cellular damage. Previous studies revealed that the pathogen A. baumannii is even more sensitive to blue light than A. kookii. Therefore, blue LED-ETTs are expected to reduce A. baumannii without harming human tracheal cells.

Standort
Deutsche Nationalbibliothek Frankfurt am Main
Umfang
Online-Ressource
Sprache
Englisch

Erschienen in
Minimum irradiance required to inhibit microbial growth to prevent ventilatorassociated pneumonia by an endotracheal tube equipped with blue LEDs ; volume:7 ; number:2 ; year:2021 ; pages:239-242 ; extent:4
Current directions in biomedical engineering ; 7, Heft 2 (2021), 239-242 (gesamt 4)

Urheber
Sicks, Ben
Stock, Christina
Peter, Sarah
Meurle, Tobias
Hoenes, Katharina
Spellerberg, Barbara
Hessling, Martin

DOI
10.1515/cdbme-2021-2061
URN
urn:nbn:de:101:1-2022101214025827986607
Rechteinformation
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Letzte Aktualisierung
15.08.2025, 07:23 MESZ

Datenpartner

Dieses Objekt wird bereitgestellt von:
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.

Beteiligte

  • Sicks, Ben
  • Stock, Christina
  • Peter, Sarah
  • Meurle, Tobias
  • Hoenes, Katharina
  • Spellerberg, Barbara
  • Hessling, Martin

Ähnliche Objekte (12)