Optimal configuration assessments of hybrid renewable power supply for rural healthcare facilities

This paper assessed optimal configurations of hybrid renewable system for rural health clinic (RHC) application in three grid-unconnected rural villages in Nigeria. The RHC consist of an emergency room, consulting room, nurse/injection room, male ward, female ward, a delivery room and a laboratory with average total daily energy consumption of 15.5 kWh and 2.75 kW peak demand. The assessment of configurations that optimally meet the daily load demand with zero loss of power supply probability (LPSP) was carried out using HOMER software, by considering three energy resources; photovoltaic (PV), wind and diesel with battery energy storage. The result obtained revealed hybrid PV/wind/diesel/battery system as the most cost-effective configuration for powering rural health clinic in both Maiduguri and Enugu sites, while that of Iseyin site was found to be hybrid PV/diesel/battery system. In all the sites, the selected optimal configuration is far better than the conventional diesel stand-alone system in terms of cost and emission reduction.

Language
Englisch

Bibliographic citation
Journal: Energy Reports ; ISSN: 2352-4847 ; Volume: 2 ; Year: 2016 ; Pages: 141-146 ; Amsterdam: Elsevier

Classification
Wirtschaft
Subject
HOMER
Hybrid energy system
Nigeria
Optimization
Rural health clinic

Event
Geistige Schöpfung
(who)
Olatomiwa, Lanre
Event
Veröffentlichung
(who)
Elsevier
(where)
Amsterdam
(when)
2016

DOI
doi:10.1016/j.egyr.2016.06.001
Handle
Last update
10.03.2025, 11:42 AM CET

Data provider

This object is provided by:
ZBW - Deutsche Zentralbibliothek für Wirtschaftswissenschaften - Leibniz-Informationszentrum Wirtschaft. If you have any questions about the object, please contact the data provider.

Object type

  • Artikel

Associated

  • Olatomiwa, Lanre
  • Elsevier

Time of origin

  • 2016

Other Objects (12)