Phacoemulsification with and without iStent: A Systematic Review and Meta-Analysis of Comparative Studies

Background: The iStent (Glaukos Corporation; Laguna Hills, CA, USA) is one of the minimally invasive glaucoma devices. It can be inserted at the time of phacoemulsification or as a stand-alone procedure to lower the intraocular pressure (IOP). Objective: Our aim was to conduct a systematic review and meta-analysis comparing the effect of iStent insertion at the time of phacoemulsification with phacoemulsification alone in patients with ocular hypertension or open-angle glaucoma. Methods: We searched EMBASE, MEDLINE (OVID and PubMed), CINAHL, and Cochrane Library for articles published between 2008 and June 2022 (PRISMA 2020 for the checklist). Studies comparing the IOP-lowering effect of iStent with phacoemulsification versus phacoemulsification alone were included. The endpoints were IOP reduction (IOPR) and the mean reduction in the number of glaucoma drops. A quality-effects model was used to compare both surgical groups. Results: Ten studies were included, reporting on 1,453 eyes. Eight hundred fifty three eyes had the combined iStent and phacoemulsification, and 600 eyes underwent phacoemulsification alone. IOPR was higher in the combined surgery at of 4.7 ± 2 mm Hg compared to 2.8 ± 1.9 mm Hg in phacoemulsification alone. A greater decrease in postoperative eye drops was noted in the combined group having a decrease of 1.2 ± 0.3 eye drops versus of 0.6 ± 0.6 drops in isolated phacoemulsification. The quality effect model showed an IOPR weighted mean difference (WMD) of 1.22 mm Hg (confidence interval [CI]: [–0.43, 2.87]; Q = 315.64; p < 0.01; I2 = 97%) and decreased eye drops WMD 0.42 drops (CI: [0.22, 0.62]; Q = 42.6; p < 0.01; I2 = 84%) between both surgical groups. Subgroup analysis shows that the new generation iStent may be more effective in reducing IOP. Conclusion: iStent has a synergetic effect with phacoemulsification. The reduction of IOP and glaucoma eye drops was higher when iStent is combined with phacoemulsification compared with isolated phacoemulsification.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Phacoemulsification with and without iStent: A Systematic Review and Meta-Analysis of Comparative Studies ; volume:66 ; number:1 ; year:2023 ; pages:1020-1029 ; extent:10
Ophthalmic research ; 66, Heft 1 (2023), 1020-1029 (gesamt 10)

Creator
Kahale, Francesca
Chanbour, Wassef
El Zein, Lulwa
Brenner, Jason
You, Jae Young
Melki, Samir

DOI
10.1159/000531077
URN
urn:nbn:de:101:1-2023122801025763042823
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:30 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Kahale, Francesca
  • Chanbour, Wassef
  • El Zein, Lulwa
  • Brenner, Jason
  • You, Jae Young
  • Melki, Samir

Other Objects (12)