Breast uptake on a myocardial perfusion scan

Abstract: A 42-year-old female underwent a myocardial perfusion scan (MPS) for the evaluation of coronary artery disease. Raw and cine loop images hinted at abnormal tracer accumulation in the chest. Review of short-axis slices and low-dose computed tomography images taken for attenuation correction and their subsequent fusion confirmed the presence of focal tracer uptake localized to nodular breast masses. This case demonstrates that despite MPS not being optimized to detect breast pathologies, careful inspection of unprocessed images and the application of available software for fusion can help detect concurrent pathology.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Breast uptake on a myocardial perfusion scan ; volume:20 ; number:01 ; year:2021 ; pages:105-108
World Journal of Nuclear Medicine ; 20, Heft 01 (2021), 105-108

Contributor
Morales, Cristina
Apostol, Angelin

DOI
10.4103/wjnm.WJNM_35_20
URN
urn:nbn:de:101:1-2022051211572032561121