R&D towards the DARWIN full-diameter Demonstrator
Abstract: During this work a design for the DARWIN full diameter demonstrator, its reinforcement structure and a holding system were designed. For weight optimizations different layouts were stress tested by Finite Element Analysis. Multiple channels of heat input were calculated and a nitrogen based thermosyphon cooler developed to provide sufficient cooling. A gas system and a testing platform were built to determine the cooler’s behaviour in the 0-100 W cooling power range. In a final step its ability to liquefy xenon was tested at 42 gram per minute
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Anmerkungen
-
Universität Freiburg, Masterarbeit, 2019
- Schlagwort
-
Zeitprojektionskammer
Dunkle Materie
- Ereignis
-
Veröffentlichung
- (wo)
-
Freiburg
- (wer)
-
Universität
- (wann)
-
2023
- Urheber
- Beteiligte Personen und Organisationen
- DOI
-
10.6094/UNIFR/239087
- URN
-
urn:nbn:de:bsz:25-freidok-2390874
- Rechteinformation
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
- 14.08.2025, 10:50 MESZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
Entstanden
- 2023