On the impact of improved dose calculation accuracy in clinical treatment planning for superficial high-dose-rate brachytherapy of extensive scalp lesions
Abstract: TG-43-based dose calculations disregard tissue heterogeneities and finite scatter conditions, prompting the introduction of model-based dose calculation algorithms (MBDCAs) to improve accuracy in high-dose-rate (HDR) brachytherapy. This study evaluated the effectiveness of MBDCAs over TG-43 in HDR 192Ir brachytherapy of extended scalp lesions. Treatment planning dose calculations were compared with Monte Carlo (MC) data. TG-43 exhibited a dose overestimation ranging from 10% to 23% as the distance from the implant increased, while a better agreement from 2% to 6% was observed between the MBDCA and MC, supporting the adoption of MBDCAs for dose calculations in broad scalp lesions
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Anmerkungen
-
Physics and Imaging in Radiation Oncology. - 32 (2024) , 100673, ISSN: 2405-6316
- Ereignis
-
Veröffentlichung
- (wo)
-
Freiburg
- (wer)
-
Universität
- (wann)
-
2024
- Urheber
-
Rossi, Giulio
Peppa, Vasiliki
Gainey, Mark
Kollefrath, Michael
Sprave, Tetyana
Papagiannis, Panagiotis
Baltas, Dimos
- DOI
-
10.1016/j.phro.2024.100673
- URN
-
urn:nbn:de:bsz:25-freidok-2603945
- Rechteinformation
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
-
15.08.2025, 07:20 MESZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
- Rossi, Giulio
- Peppa, Vasiliki
- Gainey, Mark
- Kollefrath, Michael
- Sprave, Tetyana
- Papagiannis, Panagiotis
- Baltas, Dimos
- Universität
Entstanden
- 2024