Intra-aortic balloon occlusion without fluoroscopy for life-threating post-partum hemorrhage

Abstract: The use of intra-aortic balloon occlusion (IABO) could be effective in achieving the quick control of bleeding in emergency settings and in supporting the provision of safe radical treatment through resuscitative endovascular balloon occlusion of the aorta (REBOA). We herein report our experience of a patient with life-threatening postpartum hemorrhage after cesarean section who was successfully treated by hysterectomy with IABO without fluoroscopy. We believe that this procedure is very useful and safe, and that it should be considered as one of methods for controlling bleeding in patients with life-threatening postpartum hemorrhage.

Location
Deutsche Nationalbibliothek Frankfurt am Main
Extent
Online-Ressource
Language
Englisch

Bibliographic citation
Intra-aortic balloon occlusion without fluoroscopy for life-threating post-partum hemorrhage ; volume:5 ; number:1 ; year:2016 ; pages:19-22 ; extent:4
Case reports in perinatal medicine ; 5, Heft 1 (2016), 19-22 (gesamt 4)

Creator
Yamashita, Yuka
Kawashima, Akihiro
Hasegawa, Junichi
Oba, Tomohiro
Nakamura, Masamitsu
Yamashita, Tomoyuki
Miyake, Yasufumi
Sekizawa, Akihiko

DOI
10.1515/crpm-2015-0050
URN
urn:nbn:de:101:1-2411121516138.741128438088
Rights
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
Last update
15.08.2025, 7:35 AM CEST

Data provider

This object is provided by:
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.

Associated

  • Yamashita, Yuka
  • Kawashima, Akihiro
  • Hasegawa, Junichi
  • Oba, Tomohiro
  • Nakamura, Masamitsu
  • Yamashita, Tomoyuki
  • Miyake, Yasufumi
  • Sekizawa, Akihiko

Other Objects (12)