German experience with a novel balloon-expandable heart valve prosthesis for transcatheter aortic valve implantation — outcomes of the MYLAND (MYvaL germAN stuDy) Study
Abstract: Background: The primary objective of this study was to evaluate the initial experience in Germany with the Meril Myval™ (MM) transcatheter heart valve (THV) system for the treatment of severe symptomatic aortic valve stenosis. The MM THV is a novel balloon-expandable valve with an expanded sizing matrix. Contemporary patients undergoing TAVI with the established Edwards Sapien™ (ES) THV served as the comparator group. Methods: Between 1st March and 31 August 2020 a total of 134 patients (33% female, 80.1 ± 6.7 years; EuroScore II 4.7 ± 4.8) underwent TAVI with an MM (95% transfemoral) for severe aortic stenosis at six German tertiary care centers. Results: Correct positioning of the THV was achieved in 98.5% (n = 132). Mean aortic gradients (MPG) were reduced from 42 ± 14 mmHg to 11 ± 5 mmHg. Mild postprocedural paravalvular leak (PVL) was observed in 62% (n = 82) patients, whereas only one patient had more than mild PVL. New permanent pacemaker implantation (PPI) was indicated in 15 patients (11%). Major vascular complications occurred in 6.7% (n = 9) patients. The in-hospital combined incidence of all-cause death and stroke was 4.5% (n = 6). In the comparator group that included 268 patients, the 30-day incidences of PPI, major vascular complications, and the composite of all-cause death and stroke were 16%, 1.9%, and 7.1%, respectively; MPGs were reduced from 44 ± 15 mmHg to 12.8 ± 4.6 mmHg and the more than mild PVL occurred in 0.7%. Conclusions: The MM is a promising novel THV system, with performance comparable to the established ES THVs. These findings await confirmation by ongoing randomized trials
- Standort
-
Deutsche Nationalbibliothek Frankfurt am Main
- Umfang
-
Online-Ressource
- Sprache
-
Englisch
- Anmerkungen
-
Journal of Clinical Medicine. - 13, 11 (2024) , 3163, ISSN: 2077-0383
- Ereignis
-
Veröffentlichung
- (wo)
-
Freiburg
- (wer)
-
Universität
- (wann)
-
2024
- Urheber
-
Ubben, Timm
Tigges, Eike
Kim, Won-Keun
Holzamer, Andreas
Breitenbach, Ingo
Sodian, Ralf
Rothe, Jürgen
Hochholzer, Willibald
Hakmi, Samer
Neumann, Franz-Josef
- DOI
-
10.3390/jcm13113163
- URN
-
urn:nbn:de:bsz:25-freidok-2493003
- Rechteinformation
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Letzte Aktualisierung
-
25.03.2025, 13:54 MEZ
Datenpartner
Deutsche Nationalbibliothek. Bei Fragen zum Objekt wenden Sie sich bitte an den Datenpartner.
Beteiligte
- Ubben, Timm
- Tigges, Eike
- Kim, Won-Keun
- Holzamer, Andreas
- Breitenbach, Ingo
- Sodian, Ralf
- Rothe, Jürgen
- Hochholzer, Willibald
- Hakmi, Samer
- Neumann, Franz-Josef
- Universität
Entstanden
- 2024