Risk of bacterial colonization by torniquet during arthroscopy of the knee joint
Abstract: Purpose: The following study investigated the risk of transmission or spread of potentially pathogenic bacteria via surgical gloves and/or with an elastic bandage to achieve a bloodless surgical site during arthroscopy.Methods: This was a single-center, prospective study performed at a level-1 trauma center. The included patients were between 18 and 65 years of age and underwent arthroscopy of the knee joint. Before arthroscopy, two skin swabs (one before and one after wrapping the leg with an elastic bandage) were taken for further microbiological analysis. In addition, the thumb and index finger of the right glove of the surgeon's gloves and the part of the bandage covering the knee joint was kept for microbiological examination. Results: 208 samples from 52 patients were included. No patient had a surgical site infection (SSI) during the follow-up period of at least 12 months. The evaluation of the microbiological findings detected contamination of the elastic wrapping mater...
Abstract: Zielsetzung: Es sollte das Risiko der Übertragung potenziell pathogener Bakterien über Operationshandschuhe und/oder elastische Binden während einer Arthroskopie in Blutleere untersucht werden.Methoden: Es handelt sich um eine monozentrische prospektive Studie. Die eingeschlossenen Patienten waren zwischen 18 und 65 Jahre alt und unterzogen sich einer Arthroskopie am Kniegelenk. Vor der Arthroskopie wurden zwei Hautabstriche - einer vor und einer nach dem Umwickeln des Beins mit einem elastischen Verband - zur mikrobiologischen Analyse entnommen. Zusätzlich wurden der Daumen und der Indexfinger des rechten Operationshandschuhs des Chirurgen und des Teils des Verbands, der das Kniegelenk bedeckte, zur mikrobiologischen Untersuchung asserviert.Ergebnisse: Es wurden 208 Proben von 52 Patienten eingeschlossen. Kein Patient hatte während der mindestens 12monatigen Nachbeobachtungszeit eine postoperative Wundinfektion (SSI). Die Auswertung der mikrobiologischen Befunde ergab eine Kon...
- Alternative title
-
Risiko der bakteriellen Kontamination durch eine elastische Wicklung während einer arthroskopischen Knieoperation
- Location
-
Deutsche Nationalbibliothek Frankfurt am Main
- Extent
-
Online-Ressource
- Language
-
Englisch
- Bibliographic citation
-
Risk of bacterial colonization by torniquet during arthroscopy of the knee joint ; volume:19 ; day:23 ; month:10 ; year:2024
GMS hygiene and infection control ; 19 (23.10.2024)
- Classification
-
Medizin, Gesundheit
- Creator
-
Melcher, Peter
Dietze, Nadine
Hellmund, Christoph
Hepp, Pierre
Henkelmann, Ralf
- DOI
-
10.3205/dgkh000502
- URN
-
urn:nbn:de:0183-dgkh0005022
- Rights
-
Open Access; Der Zugriff auf das Objekt ist unbeschränkt möglich.
- Last update
-
15.08.2025, 7:36 AM CEST
Data provider
Deutsche Nationalbibliothek. If you have any questions about the object, please contact the data provider.
Associated
- Melcher, Peter
- Dietze, Nadine
- Hellmund, Christoph
- Hepp, Pierre
- Henkelmann, Ralf